::: UNITECH INSTRUMENTATION :::
MUMBAI - 400 086

Compensating Cable

 
 Thermocouples are connected to indicators/controllers using special cable which are know as
 compensating cable. In cases where accuracy of reading is of prime importance cables with
 original conductor is used such cable is known as extension cable.
 
 The cables are manufactured in various configurations. We are giving below various types of
 cable constructions available.
 

OUTER INSULATION

  AREA
MM2
GAUGE MAXIMUM TEMP COLOUR
CODING
PAIRS

HR PVC INSULATED CABLE

0.2 mm2
0.5 mm2
1.3 mm2

1 X 25 SWG
1 X 21 SWG
1 X 18 SWG

-25 TO 75 Deg C

BS /
ANSI
IEC

SIMPLEX
OR DUPLEX

FLAME RETARDANT
PVC INSULATED CABLE

1.2 mm2
2.0 mm2

3 X 22 SWG
3 X 20 SWG

-25 TO +85 Deg C.

BS /
ANSI
IEC

SIMPLEX
OR
DUPLEX

TEFLON INSULATED CABLE

0.22 mm2
0.44 mm2
0.75 mm2

7 X 36 SWG
14 X 36 SWG
32 X 36 SWG

0 TO 225 Deg C

BS /
ANSI
IEC

SIMPLEX
OR
DUPLEX

FIBRE GLASS INSULATED
CABLE

1.00 mm2
1.30 mm2
2.00 mm2

24 X 36 SWG
40 X 36 SWG
64 X 36 SWG

0 TO 350 Deg C

BS / ANSI
IEC

SIMPLEX
OR
DUPLEX

Note:
Fibreglass cables are normally supplied with SS wire braiding. Teflon cable can be supplied with SS braiding if required. HRPVC, Flame retadrant PVC and Teflon cable can be supplied with Copper drain wire and Aluminium mylar for Noise rejection.

 Compensating Cables:
 Compensating cables are manufactured
 from conductors having composition different
 from corresponding thermocouples.
 They are designated by letter “C” following the
 designation of the thermocouple. Eg: TC
 

 Extension Cables:
 Extension cables are manufactured from
 conductors having composition same as that of
 from corresponding thermocouples.
 They are designated by letter “X” following the
 designation of the thermcouple. Eg: TX